Carrier CE, PE, CQ, & PQ Series PTAC Configuration Guide
|
Remote Thermostat Interface |
Remote Thermostat Interface Image |
|
Screw Terminal |
![]() |
CE, PE, CQ, & PQ Series Remote Thermostat Enable:
|
Steps |
Image |
|
|
1 |
Unplug the PTAC |
|
|
2 |
Remove PTAC terminal connector from PTAC, wire Anacove screw terminal wiring harness to terminal connecter, and plug terminal connector back into PTAC |
There is no specific button sequence or switch that needs to be triggered in order to enable remote thermostat mode |
|
3 |
Plug the PTAC back in |
AN40400 - Screw terminal PTAC wiring harness color coding guide:
***Unused Anacove Wiring Harness wires should be removed from the Wiring Harness. Cut the wire off approximately 1/2" from the HVAC Controller end of the harness***
|
Anacove Wire Color |
CE, PE, CQ, & PQ Remote Thermostat Interface |
|
Red |
R |
|
Black |
C |
|
White |
W |
|
Yellow |
Y |
|
Green |
GL |
|
Brown |
GH |
|
Blue |
Not Used |
|
Orange |
O |