Screenshot 2023-03-01 145210

Islandaire EZxxxxGSxxxxxxx PTAC Configuration Guide

 

***If the unit has a rotary/mechanical dial for the temperature control it is not compatible to have a remote thermostat installed. Anacove’s Screw Terminal Wiring Harness (AN40400) is connected to the Islandaire remote thermostat pigtail by connecting the wires with wire nuts***

Remote Thermostat Interface

Remote Thermostat Interface Image

Pin Header

6e348c86-11d4-404f-920c-ea48d636f832

 

EZxxxxGSxxxxxxx Remote Thermostat Enable:

 

Step

Image

1

Turn PTAC off on user controls

a76d3707-e141-4410-8617-a75e3518a1f7

 

2

Press and hold the MODE and WARM buttons simultaneously for 3 seconds

A buzzer will chime

3

The display should read "r"

If the display reads "P" then repeat step 2 until it reads "r"

 

AN40400 - Screw terminal PTAC wiring harness color coding guide:

***Unused Anacove Wiring Harness wires should be removed from the Wiring Harness. Cut the wire off approximately 1/2" from the HVAC Controller end of the harness***

Anacove Wire Color

EZxxxxGSxxxxxxx Remote Thermostat Interface Wire Color

Red

R/RED

Black

C/BLACK

White

W/WHITE

Yellow

Y/YELLOW

Green

GL/ORANGE

Brown

GH/GREEN

Blue

B/BLUE

Orange

Not Used