Hybrid Advantage HCxxxxxx-Cx PTAC Configuration Guide
Remote Thermostat Interface |
Remote Thermostat Interface Image |
Screw Terminal |
![]() |
HCxxxxxx-Cx Remote Thermostat Enable:
Step |
Image |
|
1 |
Unplug the PTAC from power |
|
2 |
Remove the two screws on the metal plate that covers the Remote Thermostat Interface of the PTAC |
![]() |
3 |
Move dip switch S3 to UP (ON) and move dip switch S9 to DOWN (OFF). Make sure dip switches S4 and S5 are in the UP (ON) position as well |
![]() |
4 |
Wire up the Anacove Screw Terminal Wiring Harness wires to the PTAC's Remote Thermostat Interface according to the below color coding guide |
PTAC Remote Thermostat Interface terminals HEAT2, FC(N), and FC(L) are not used and should have no wires connected to them |
5 |
Reattach the metal plate that covers the Remote Thermostat Interface of the PTAC |
|
6 |
Plug the PTAC back into power |
AN40400 - Screw terminal PTAC wiring harness color coding guide:
***Unused Anacove Wiring Harness wires should be removed from the Wiring Harness. Cut the wire off approximately 1/2" from the HVAC Controller end of the harness***
Anacove Wire Color |
HCxxxxxx-Cx Remote Thermostat Interface |
Red |
24V(L) |
Black |
24V(N) |
White |
HEAT 1 |
Yellow |
COMP |
Green |
LOW-FAN |
Brown |
HI-FAN |
Blue |
4-WAY |
Orange |
Not Used |
Hybrid Advantage PTAC HVAC Controller Gateway Mounting Placement |
![]()
|