GE AZ45E & AZ65H PTAC Configuration Guide
Remote Thermostat Interface |
Remote Thermostat Interface Image |
Pin Header These models could use an Anacove GE 7-Pin or a GE 8-Pin Wiring Harnesses Check the Remote Thermostat Connector Socket port to confirm the number of pins and the proper wiring harness to utilize |
![]() |
AZ45E & AZ65H Series Remote Thermostat Enable:
***If after pressing the red Aux Set button the user interface begins to flash it means that the display controls have been locked out. In order to correct this, hold down the Display button for 10 seconds***
Steps |
Image |
|
1 |
Turn the unit off at the control panel. The unit needs power but the On/Off button should be off |
|
2 |
Lift the front cover off and press the red Aux Set button |
![]() |
3 |
Press the mode button until the first digit of the LED display reads "6" |
![]() |
4 |
Press the + button until the digit next to the 6 is an "n" |
![]() |
5 |
Press the red Aux Set button to save the Use Wall Thermostat setting |
|
6 |
The backlit display should read "Use Wall Thermostat" to confirm the sequence was completed successfully |
![]() |
GE PTAC HVAC Controller Gateway Mounting Placement |
![]()
|