Screenshot 2023-03-01 145210

GE AZ41E & AZ61H PTAC Configuration Guide

 

Remote Thermostat Interface

Remote Thermostat Interface Image

Screw Terminal

2725ded2-0ebb-480e-8236-bb0ad8b5acb5

 

GE AZ41E & AZ61H Series Remote Thermostat Enable:

 

Steps

Image

1

Turn the unit off at the control panel. The unit needs power but the On/Off button should be off

 

2

Lift the front cover off and press the red Aux Set button

e74ec749-f758-4107-bac3-13b83a7c175e

3

Press the mode button until the first digit of the LED display reads "6"

b85ec9dc-fa09-4761-acf4-9b357ecab412

4

Press the + button until the digit next to the 6 is an "n"

938ee739-5e25-474b-86d1-6956b843fa0b

5

Press the red Aux Set button to save the Use Wall Thermostat setting

 

6

The backlit display should read "Use Wall Thermostat" to confirm the sequence was completed successfully

e0196f36-8f30-4d8e-9cd5-d2d96eb8dddb

 

AN40400 - Screw terminal PTAC wiring harness color coding guide:

***Unused Anacove Wiring Harness wires should be removed from the Wiring Harness. Cut the wire off approximately 1/2" from the HVAC Controller end of the harness***

Anacove Wire Color

AZ41E & AZ61H Remote Thermostat Interface

Red

R

Black

C

White

W

Yellow

Y

Green

GL

Brown

GH

Blue

B

Orange

Not Used